Thermal Imaging & Inspection
Calibrated radiometric thermal capture for roof moisture mapping, PV array fault-finding, and electrical inspection. You receive the radiometric files themselves, so your engineer can pull temperatures at any point rather than trusting our screenshot.
- Starting at
- $750
- per inspection
- Turnaround
- 3 business days
- Coverage
- 120 mi
- from LA metro
Deliverables
What lands in your hands
- Radiometric R-JPEG files for FLIR Tools or Raptor Maps
- Thermal orthomosaic keyed to array string or roof section
- Matched RGB reference imagery for every anomaly
- Written findings summary with anomaly count and severity
- Annotated exhibits suitable for warranty and repair scoping
Typical use cases
- Roof moisture surveys before re-roof or after a storm
- Annual PV array inspection and O&M reporting
- Electrical service and substation fault-finding
- Building envelope and heat-loss assessment

Specifications
- Sensor
- 640x512 radiometric, 30 Hz
- Capture
- Thermal and RGB on the same pass
- Window
- Flown at optimal thermal delta
- Output
- R-JPEG · CSV · thermal orthomosaic
Process
How the job runs
01
Pick the thermal window
Roof surveys fly after sunset when trapped moisture reads hottest. PV arrays fly under load at full irradiance. The window matters more than the sensor.
02
Fly the survey
Gridded thermal capture with simultaneous RGB, at an altitude that keeps resolution above the anomaly detection threshold.
03
Analyze
Anomalies are located, classified by severity, and tied to a roof section or array string.
04
Report
Findings summary plus the raw radiometric files, so anyone downstream can verify the numbers.
Who books this
Industries this service is built for
Real Estate
Listing media that moves properties faster
Aerial stills and video that show lot lines, proximity, and scale in a way ground photography cannot.
See the industry pageConstruction
Documented progress your owner and your subs both trust
Repeatable flight plans flown from the same waypoints every visit, so month three lines up with month one.
See the industry pageInspection
Radiometric data, not just pretty pictures
Roof moisture surveys, PV array fault-finding, and infrastructure condition assessment flown with calibrated radiometric sensors.
See the industry pageQuestions
About thermal inspection
Do you provide a certified thermography report?
We provide the radiometric data, anomaly mapping, and a findings summary. Where a stamped Level II thermographer report is required, we work alongside your thermographer or refer one.
Why does a roof scan have to be at night?
Wet insulation holds heat longer than dry insulation. After sunset the dry roof cools and the wet areas glow. Fly it at noon and you see nothing but sun load.