Thermal Imaging & Inspection

Calibrated radiometric thermal capture for roof moisture mapping, PV array fault-finding, and electrical inspection. You receive the radiometric files themselves, so your engineer can pull temperatures at any point rather than trusting our screenshot.

Starting at
$750
per inspection
Turnaround
3 business days
Coverage
120 mi
from LA metro

Deliverables

What lands in your hands

  • Radiometric R-JPEG files for FLIR Tools or Raptor Maps
  • Thermal orthomosaic keyed to array string or roof section
  • Matched RGB reference imagery for every anomaly
  • Written findings summary with anomaly count and severity
  • Annotated exhibits suitable for warranty and repair scoping

Typical use cases

  • Roof moisture surveys before re-roof or after a storm
  • Annual PV array inspection and O&M reporting
  • Electrical service and substation fault-finding
  • Building envelope and heat-loss assessment
Thermal Imaging & Inspection

Specifications

Sensor
640x512 radiometric, 30 Hz
Capture
Thermal and RGB on the same pass
Window
Flown at optimal thermal delta
Output
R-JPEG · CSV · thermal orthomosaic

Process

How the job runs

  1. 01

    Pick the thermal window

    Roof surveys fly after sunset when trapped moisture reads hottest. PV arrays fly under load at full irradiance. The window matters more than the sensor.

  2. 02

    Fly the survey

    Gridded thermal capture with simultaneous RGB, at an altitude that keeps resolution above the anomaly detection threshold.

  3. 03

    Analyze

    Anomalies are located, classified by severity, and tied to a roof section or array string.

  4. 04

    Report

    Findings summary plus the raw radiometric files, so anyone downstream can verify the numbers.

Questions

About thermal inspection

Do you provide a certified thermography report?

We provide the radiometric data, anomaly mapping, and a findings summary. Where a stamped Level II thermographer report is required, we work alongside your thermographer or refer one.

Why does a roof scan have to be at night?

Wet insulation holds heat longer than dry insulation. After sunset the dry roof cools and the wet areas glow. Fly it at noon and you see nothing but sun load.

Get started

Request a thermal inspection quote

Tell us the site and the deliverable. Most quotes go back the same business day.

Same-business-day response on quotes.

Tell us what you need documented

Send the address, the deliverable, and your target date. Most quotes go back the same business day.